AC/DC Electrician and photovoltaic technician
- Employment type
- Full-time
- Location
- Crissier
- Company
- GTS SA, Chemin des Lentillières 24, 1023 Crissier
- First posted
AC/DC Electrician and photovoltaic technician
AC/DC Electrician and photovoltaic technician (100 %)
Autonomous AC sites · DC commissioning · monitoring
JOB INFORMATION
- Job title: AC/DC Electrician and photovoltaic technician
- Activity rate: 100 %
- Reporting to: Project Manager / technical manager
- Base: GTS headquarters; sites in French-speaking Switzerland
- Required qualification: CFC electrical installer — copy to be attached to the application
- License: Category B required
- Start date: To be agreed
- THE JOB IN BRIEF
Carry out the electrical part of GTS photovoltaic installations — AC and DC — and independently manage AC sites: material, planning, execution, measurements, reports. Commission, measure, document, and make an installation functional and compliant.
The job is:
- Pulling, connecting, measuring, commissioning, and documenting.
- Taking an AC site and managing it from start to finish without continuous supervision.
- Being the technical reference on the ground when an installation malfunctions.
The job is not:
- Module installation on a daily basis: the mechanical part is done by the assembly teams.
- An office job: the field remains the heart of the profession.
- A position without progression.
Typical volume:
- From residential to industrial buildings. Common objects from 10 to 500 kWp, with larger power projects growing.
- AC PART — REQUIRED
This is the core of the job. You must know how to do it alone from the start.
Installation and connection
- Installation and connection of panels: AC enclosures, TGBT, protections, RCD, surge protectors, disconnectors, measuring devices.
- Pulling and connecting power cables, controlled sizing on site, cable trays, firestop passages.
- Earthing and equipotential bonding: implementation and verification.
- Connection to the injection point, coordination with the GRD, installation and parameter setting of meters and production metering.
- Rework and modification of existing installations: identification of circuits, planned outages, recommissioning.
Autonomous management of an AC site
A entrusted AC site must return finished, measured, and documented.
- Read the technical file, identify what is missing, and clarify before starting.
- Establish the complete material list and transmit it in time for the order.
- Plan your own work: order of steps, durations, coordination with other trades and with the project manager.
- Organize the necessary means: access, scaffolding, aerial work platform, outages, access authorizations.
- Occasionally supervise an apprentice or a fitter on the AC part.
- Maintain the daily report, hours, and progress photos.
- Immediately report any deviation in deadline, cost, or feasibility — as early as possible.
Measurements, safety and documents
Without documents, the site is not finished.
- Own control of the installation according to NIBT and OIBT.
- Complete measurement protocols: continuity of the protective conductor, insulation resistance, loop impedance, short-circuit current, RCD control, phase order, earth measurement.
- Establishment of the safety report and annexes, within deadlines and without rework.
- Compliance with occupational safety rules: five safety rules, lockout/tagout, PPE, live work prohibited except by procedure.
- Reporting of non-conformities observed on existing installations encountered.
- DC PART, COMMISSIONING AND MONITORING — DESIRABLE
Desirable at the start, indispensable in the long term. If not acquired, training is provided by us — see chapter 6.
DC side
- String wiring, connectivity, DC enclosures, disconnectors, surge protectors, routing, and fixings.
- Control of strings before powering up: polarity, open-circuit voltage, insulation resistance, short-circuit current.
- I-V curve measurement and interpretation; searching for string faults, insulation faults, and arcs.
- Control thermography and reading of results.
Inverter commissioning
- Commissioning and parameter setting of string and central inverters: grid settings, power curves, injection limitation, decoupling protection.
- Parameter setting in accordance with GRD requirements and current connection regulations.
- Drafting of the commissioning protocol and the record of applied parameters.
- Diagnosis and treatment of inverter faults, exchange under warranty, relationship with manufacturer support.
Monitoring and IT
- Installation and configuration of monitoring: gateways, meters, sensors, communication buses (Modbus RTU/TCP, RS485), irradiation and temperature probes.
- Networking: IP addressing, VLAN, 4G router, VPN, ports, client-side firewall — knowing how to communicate with an IT department.
- Control of data upload, alarms and thresholds, creation of client access.
- Analysis of a production deviation: distinguishing an installation fault, a hardware fault, shading, and a parameter setting error.
- LARGE POWER, CHARGING STATIONS AND BATTERIES — ASSETS
Not required at the start, but these are the growing areas at GTS. Experience in one of them is a real plus.
Installations > 500 kVA
- Power panels, busbars, large cross-section cables, connections on transformer.
- Selectivity, coordination of protections, decoupling protection, grid quality control.
- Coordination with the GRD on connection conditions and compliance tests.
Charging stations
- Installation, connection, and commissioning of AC and DC stations.
- Dynamic load management, load shedding, metering, communication, and supervision (OCPP).
- Coordination with the building's available power and PV self-consumption.
Battery storage
- Installation, connection, and commissioning of storage systems.
- Parameter setting of operating modes: autocon
Automatically translated from the original.
Posted 2 weeks ago